如何診斷RAC數據庫上的“IPC Send timeout”問題

 RAC 數據庫上比較常見的一種問題就是“IPC Send timeout”。數據庫Alert log中出現了“IPC Send timeout”之後,經常會伴隨着ora-29740 或者 "Waiting for clusterware split-brain resolution"等,數據庫實例會因此異常終止或者被驅逐出集羣。

比如:

實例1的ALERT LOG:

Thu Jul 02 05:24:50 2012
IPC Send timeout detected.Sender: ospid 6143755<==發送者
Receiver: inst 2 binc 1323620776 ospid 49715160<==接收者

Thu Jul 02 05:24:51 2012
IPC Send timeout to 1.7 inc 120 for msg type 65516 from opid 13
Thu Jul 02 05:24:51 2012
Communications reconfiguration: instance_number 2
Waiting for clusterware split-brain resolution <==出現腦裂
Thu Jul 02 05:24:51 2012
Trace dumping is performing id=[cdmp_20120702052451]
Thu Jul 02 05:34:51 2012
Evicting instance 2 from cluster <==過了10分鐘,實例2被驅逐出集羣

實例2的ALERT LOG:

Thu Jul 02 05:24:50 2012
IPC Send timeout detected. Receiver ospid 49715160 <==接收者
Thu Jul 02 05:24:50 2012
Errors in file /u01/oracle/product/admin/sales/bdump/sales2_lms6_49715160.trc:
Thu Jul 02 05:24:51 2012
Waiting for clusterware split-brain resolution
Thu Jul 02 05:24:51 2012
Trace dumping is performing id=[cdmp_20120702052451]
Thu Jul 02 05:35:02 2012
Errors in file /u01/oracle/product/admin/sales/bdump/sales2_lmon_6257780.trc:
ORA-29740: evicted by member 0, group incarnation 122  <==實例2出現ORA-29740錯誤,並被驅逐出集羣
Thu Jul 02 05:35:02 2012
LMON: terminating instance due to error 29740
Thu Jul 02 05:35:02 2012
Errors in file /u01/oracle/product/admin/sales/bdump/sales2_lms7_49453031.trc:
ORA-29740: evicted by member , group incarnation

    在RAC實例間主要的通訊進程有LMON, LMD, LMS等進程。正常來說,當一個消息被髮送給其它實例之後,發送者期望接收者會回覆一個確認消息,但是如果這個確認消息沒有在指定的時間內收到(默認300秒),發送者就會認爲消息沒有達到接收者,於是會出現“IPC Send timeout”問題。

    這種問題通常有以下幾種可能性:
1. 網絡問題造成丟包或者通訊異常。
2. 由於主機資源(CPU、內存、I/O等)問題造成這些進程無法被調度或者這些進程無響應。
3. Oracle Bug.

   在這方面的Oracle Bug不是太多,大多數時候都是網絡或者資源問題造成這種情況。

   爲了分析這種問題,網絡和資源監控工具是非常必要的。推薦安裝OSWBB,對於如何安裝和使用OSWBB,請參考文章利器OSW (OSWatcher Black Box) 之簡介篇

   下面是一個由於主機資源緊張造成的“IPC Send timeout”例子:

   實例1的Alert log中顯示接收者是2號機的進程1596935,

Fri Aug 01 02:04:29 2008 
 IPC Send timeout detected.Sender: ospid 1506825 <==發送者
 Receiver: inst 2 binc -298848812 ospid 1596935  <==接收者

   查看當時2號機的OSWatcher的vmstat輸出:

 zzz ***Fri Aug 01 02:01:51 CST 2008 
 System Configuration: lcpu=32 mem=128000MB 
 kthr     memory             page              faults        cpu     
 ----- ----------- ------------------------ ------------ ----------- 
  r  b   avm   fre  re  pi  po  fr   sr  cy  in   sy  cs us sy id wa 
 25  1 7532667 19073986   0   0   0   0    5   0 9328 88121 20430 32 10 47 11 
58  0 7541201 19065392   0   0   0   0    0   0 11307 177425 10440 87 13  0  0 <==idle的CPU爲0,說明CPU100%被使用
61
  1 7552592 19053910   0   0   0   0    0   0 11122 206738 10970 85 15  0  0 

 zzz ***Fri Aug 01 02:03:52 CST 2008 
   System Configuration: lcpu=32 mem=128000MB 
   kthr     memory             page              faults        cpu     
 ----- ----------- ------------------------ ------------ ----------- 
  r  b   avm   fre  re  pi  po  fr   sr  cy  in   sy  cs us sy id wa 
 25  1 7733673 18878037   0   0   0   0    5   0 9328 88123 20429 32 10 47 11 
81  0 7737034 18874601   0   0   0   0    0   0 9081 209529 14509 87 13  0  0 <==CPU的run queue非常高
80
  0 7736142 18875418   0   0   0   0    0   0 9765 156708 14997 91  9  0  0 <==idle的CPU爲0,說明CPU100%被使用

  上面這個例子說明當主機CPU負載非常高的時候,接收進程無法響應發送者,從而引發了“IPC Send timeout”。

  下面是一個由於網絡問題造成的“IPC Send timeout”例子:

   實例1的Alert log中顯示接收者是2號機的進程49715160,

Thu Jul 02 05:24:50 2012
IPC Send timeout detected.Sender: ospid 6143755 <==發送者
Receiver: inst 2 binc 1323620776 ospid 49715160 <==接收者

   查看當時2號機的OSWatcher的vmstat輸出,沒有發現CPU和內存緊張的問題,查看OSWatcher的netstat輸出,在發生問題前幾分鐘,私網的網卡上有大量的網絡包傳輸。

Node2:
zzz Thu Jul 02 05:12:38 CDT 2012
Name  Mtu   Network     Address            Ipkts Ierrs    Opkts Oerrs  Coll
en1   1500  10.182.3    10.182.3.2       4073847798     0 512851119     0     0 <==4073847798 - 4073692530 = 155268 個包/30秒

zzz Thu Jul 02 05:13:08 CDT 2012
Name  Mtu   Network     Address            Ipkts Ierrs    Opkts Oerrs  Coll
en1   1500  10.182.3    10.182.3.2       4074082951     0 513107924     0     0 <==4074082951 - 4073847798 = 235153 個包/30秒

Node1:
zzz Thu Jul 02 05:12:54 CDT 2012
Name  Mtu   Network     Address            Ipkts Ierrs    Opkts Oerrs  Coll
en1   1500  10.182.3    10.182.3.1       502159550     0 4079190700     0     0 <==502159550 - 501938658 = 220892 個包/30秒

zzz Thu Jul 02 05:13:25 CDT 2012
Name  Mtu   Network     Address            Ipkts Ierrs    Opkts Oerrs  Coll
en1   1500  10.182.3    10.182.3.1       502321317     0 4079342048     0     0 <==502321317 - 502159550 = 161767 個包/30秒

查看這個系統正常的時候,大概每30秒傳輸幾千個包:

zzz Thu Jul 02 04:14:09 CDT 2012
Name  Mtu   Network     Address            Ipkts Ierrs    Opkts Oerrs  Coll
en1   1500  10.182.3    10.182.3.2       4074126796     0 513149195     0     0 <==4074126796 - 4074122374 = 4422個包/30秒

   這種突然的大量的網絡傳輸可能會引發網絡傳輸異常。對於這種情況,需要聯繫網管對網絡進行檢查。在某些案例中,重啓私網交換機或者調換了交換機後問題不再發生。(請注意,網絡的正常的傳輸量會根據硬件和業務的不同而不同。)


下面是一個由於I/O問題造成的“IPC Send timeout”例子:

   實例的Alert log中顯示接收者是1號機的LMON進程:

Sun Feb 22 07:57:30 2014
IPC Send timeout detected. Receiver ospid 44105801 [oracle@db1 (LMON)] <========================接收者

查看這個進程生成的trace文件db1_lmon_44105801.trc,發現當時LMON的函數都是和IO有關的:

kjxgmpoll: stalled for 94 seconds (threshold 42 sec)

----- Call Stack Trace -----
skdstdst <- ksedst1 <- ksedst <- dbkedDefDump <- ksedmp
       <- ksdxfdmp <- ksdxcb <- sspuser <- 48bc <- sigthreadmask
        <- sslsstehdlr <- sslsshandler <- 48bc <- skgfsio <- skgfqio
         <- ksfd_skgfqio <- ksfd_io <- ksfdread <- kfk_ufs_sync_io <- kfk_submit_ufs_io
          <- kfk_submit_io <- kfk_io1 <- kfkRequest <- kfk_transitIO <- kfioSubmitIO 

           <- kfioRequestPriv <- kfioRequest <- ksfd_kfioRequest <- 576 <- ksfd_osmio
            <- ksfd_io <- ksfdread <- kccrbp <- kccgrd <- kjxgrf_rr_read
             <- kjxgrDD_rr_read <- kjxgrimember <- kjxggpoll <- kjfmact <- kjfdact
              <- kjfcln <- ksbrdp <- opirip <- opidrv <- sou2o
               <- opimai_real <- ssthrdmain <- main <- start

   總結一下,對於“IPC Send timeout”:
1) 通過Oracle自帶的CHM (Cluster Health Monitor)的輸出來檢查當時的資源、網絡使用情況。CHM只在某些平臺和版本上存在,關於CHM,請參考文章11gR2 新特性:Oracle Cluster Health Monitor(CHM)簡介
2) 如果沒有CHM,請安裝OSWBB來監控網絡和主機資源。
3) 檢查網絡上是否有UDP或者IP包丟失的情況、網絡上是否有錯誤。
4) 檢查所有節點的網絡設置是否正確。比如,所有節點MTU的設置必須是一致的,如果Jumbo Frame被使用的話,需要保證交換機可以支持MTU爲9000.
5) 檢查服務器是否有CPU使用率高或者內存不足的情況。
6) 檢查實例被驅逐之前是否有數據庫hang或者嚴重的性能問題。


  在下面的MOS文檔中有針對“IPC Send timeout”的介紹:
  Top 5 issues for Instance Eviction (Doc ID 1374110.1)