配置Cisco VSS

思科VSS配置
一、將2臺VSS65從單機箱模式切換到虛擬機箱模式
基本步驟:
1.分別在交換機1、2上配置SSO高可用性協議:
2.配置虛擬交換機的域(Virtual Switch Domain and Switch Numbers)
3.配置兩臺交換機之間的VSL 端口(利用引擎上的2個萬兆光口進行連接)
4.轉換機箱變成虛擬交換機模式

詳細配置:
1.分別在交換機1、2上配置SSO高可用性協議:
Switch1:
Step 1 
Switch-1(config)# redundancy
Enters redundancy configuration mode.
Step 2 
Switch-1(config-red)# mode sso
Configures SSO. When this command is entered, the redundant supervisor engine is reloaded and begins to work in SSO mode.
Step 3 
Switch-1(config-red)# exit

Switch-1# show running-config
Switch-1# show redundancy states  //Displays the operating redundancy mode.

Switch2:
Switch-2(config)# redundancy
Switch-2(config-red)# mode sso
Switch-2(config-red)# exit

Switch-2# show running-config
Switch-2# show redundancy states

2.配置虛擬交換機的域(Virtual Switch Domain and Switch Numbers)
Switch1:
Step 1 
Switch-1(config)# switch virtual domain 100 
Step 2 
Switch-1(config-vs-domain)# switch 1
Step 3 
Switch-1(config-vs-domain)# exit

Switch2:
Switch-2(config)# switch virtual domain 100  
Switch-2(config-vs-domain)# switch 2
Switch-2(config-vs-domain)# exit

3.配置兩臺交換機之間的VSL 端口(利用引擎上的2個萬兆光口進行連接)
1)配置channel
Switch1:
Step 1 
Switch-1(config)# interface port-channel 10
Step 2 
Switch-1(config-if)# switch virtual link 1
Step 3 
Switch-1(config-if)# no shutdown  //Activates the port channel.
Step 4 
Switch-1(config-if)# exit

Switch2:
Switch-2(config)# interface port-channel 20
Switch-2(config-if)# switch virtual link 2
Switch-2(config-if)# no shutdown
Switch-2(config-if)# exit

2)把引擎上的萬兆端口加入channel(假設引擎在slot3,一定先確認port-channel已加入switch virtual link)
Switch1:
Switch-1(config)# interface range tengigabitethernet 3/1-2
Switch-1(config-if)# channel-group 10 mode on
Switch-1(config-if)# no shutdown

Switch2:
Step 1 
Switch-2(config)# interface range tengigabitethernet 3/1-2
Switch-2(config-if)# channel-group 20 mode on
Switch-2(config-if)# no shutdown

4.轉換機箱變成虛擬交換機模式
1)先查看機箱的PFC模式,保證2個機箱相同
Step 1 
Switch-1# show platform hardware pfc mode  
Ensures that the PFC operating mode matches on both chassis, to ensure that the VSS comes up in SSO redundancy mode.
Step 2 
Switch-2# show platform hardware pfc mode
Step 3 
Switch-1(config)# platform hardware vsl pfc mode pfc3c
(Optional) Sets the PFC operating mode to PFC3C on Chassis A.
Step 4 
Switch-2(config)# platform hardware vsl pfc mode pfc3c
(Optional) Sets the PFC operating mode to PFC3C on Chassis B.

2)切換機箱模式
Switch1:
Switch-1# switch convert mode virtual
Converts Switch 1 to virtual switch mode.
After you enter the command, you are prompted to confirm the action. Enter yes.
The system creates a converted configuration file, and saves the file to the RP bootflash.

Switch2:
Switch-2# switch convert mode virtual


5.查看VSS信息
Router# show switch virtual
Displays the virtual switch domain number, and the switch number and role for each of the chassis.

Router# show switch virtual role
Displays the role, switch number, and priority for each of the chassis in the VSS.

Router# show switch virtual link
Displays the status of the VSL.

The following example shows the information output from these commands:
Router# show switch virtual
Switch mode                  : Virtual Switch
Virtual switch domain number : 100
Local switch number          : 1
Local switch operational role: Virtual Switch Active
Peer switch number           : 2
Peer switch operational role : Virtual Switch Standby

Router# show switch virtual role
Switch  Switch Status  Preempt    Priority  Role     Session ID
        Number         Oper(Conf) Oper(Conf)         Local  Remote
------------------------------------------------------------------
LOCAL    1     UP      FALSE(N)   100(100)  ACTIVE   0      0  
REMOTE   2     UP      FALSE(N)   100(100)  STANDBY  8158   1991

In dual-active recovery mode: No

Router# show switch virtual link
VSL Status: UP
VSL Uptime: 4 hours, 26 minutes
VSL SCP Ping: Pass OK
VSL ICC (Ping): Pass
VSL Control Link: Te 1/5/1


 