MegaCli和storcli設置熱備盤

MegaCli和storcli設置熱備盤

查看已創建的VD

MegaCli命令

MegaCli -LDInfo -Lall -aall

執行結果

[root@kylin ~]# MegaCli -LDInfo -Lall -aall


Adapter 0 -- Virtual Drive Information:
Virtual Drive: 0 (Target Id: 0)
Name                :
RAID Level          : Primary-5, Secondary-0, RAID Level Qualifier-3
Size                : 1.089 TB
Sector Size         : 512
Is VD emulated      : No
Parity Size         : 558.406 GB
State               : Optimal
Strip Size          : 256 KB
Number Of Drives    : 3
Span Depth          : 1
Default Cache Policy: WriteBack, ReadAhead, Cached, Write Cache OK if Bad BBU
Current Cache Policy: WriteBack, ReadAhead, Cached, Write Cache OK if Bad BBU
Default Access Policy: Read/Write
Current Access Policy: Read/Write
Disk Cache Policy   : Enabled
Encryption Type     : None
Bad Blocks Exist: No
Is VD Cached: No


Virtual Drive: 1 (Target Id: 1)
Name                :
RAID Level          : Primary-1, Secondary-0, RAID Level Qualifier-0
Size                : 1.089 TB
Sector Size         : 512
Is VD emulated      : No
Mirror Data         : 1.089 TB
State               : Optimal
Strip Size          : 256 KB
Number Of Drives per span:2
Span Depth          : 2
Default Cache Policy: WriteBack, ReadAhead, Cached, Write Cache OK if Bad BBU
Current Cache Policy: WriteBack, ReadAhead, Cached, Write Cache OK if Bad BBU
Default Access Policy: Read/Write
Current Access Policy: Read/Write
Disk Cache Policy   : Enabled
Encryption Type     : None
Bad Blocks Exist: No
Is VD Cached: No


Virtual Drive: 2 (Target Id: 2)
Name                :
RAID Level          : Primary-5, Secondary-0, RAID Level Qualifier-3
Size                : 1.089 TB
Sector Size         : 512
Is VD emulated      : No
Parity Size         : 558.406 GB
State               : Optimal
Strip Size          : 256 KB
Number Of Drives    : 3
Span Depth          : 1
Default Cache Policy: WriteBack, ReadAhead, Cached, Write Cache OK if Bad BBU
Current Cache Policy: WriteBack, ReadAhead, Cached, Write Cache OK if Bad BBU
Default Access Policy: Read/Write
Current Access Policy: Read/Write
Disk Cache Policy   : Enabled
Encryption Type     : None
Bad Blocks Exist: No
Is VD Cached: No



Exit Code: 0x00

storcli命令

storcli /call /vall show

執行結果

[root@kylin ~]# storcli /call /vall show
Controller = 0
Status = Success
Description = None


Virtual Drives :
==============

--------------------------------------------------------------
DG/VD TYPE   State Access Consist Cache Cac sCC     Size Name 
--------------------------------------------------------------
0/0   RAID5  Optl  RW     No      RAWBC -   ON  1.089 TB      
2/1   RAID10 Optl  RW     No      RAWBC -   ON  1.089 TB      
1/2   RAID5  Optl  RW     No      RAWBC -   ON  1.089 TB      
--------------------------------------------------------------

Cac=CacheCade|Rec=Recovery|OfLn=OffLine|Pdgd=Partially Degraded|dgrd=Degraded
Optl=Optimal|RO=Read Only|RW=Read Write|HD=Hidden|TRANS=TransportReady|B=Blocked|
Consist=ConsistentR=Read Ahead Always|NR=No Read Ahead|WB=WriteBack|
AWB=Always WriteBack|WT=WriteThrough|C=Cached IO|D=Direct IO|sCC=Scheduled
Check Consistency

需要關注的是,storcli命令執行結果裏的DG/VD。
1. DG編號對應的應該是硬RAID創建的先後順序,這是一個關鍵信息,因爲後面設置熱備盤的時候需要用到。
2. VD編號是和硬RAID在操作系統裏對應的盤符的關鍵信息。

MegaCli命令執行結果無法查看到DG,如”Virtual Drive: 2 (Target Id: 2)”中,對應的2爲VD編號。

硬RAID設置熱備盤分爲兩種:
1. 全局熱備。
2. 針對某個VD的熱備。

熱備盤設置命令:

MegaCli -PDHSP {-Set [-Dedicated [-ArrayN|-Array0,1,2...]] [-EnclAffinity] [-nonRevertible]} 
     |-Rmv -PhysDrv[E0:S0,E1:S1,...] -aN|-a0,1,2|-aALL

全局熱備:GHSP
全局熱備比較簡單,將要設置熱備的磁盤加到對應的adapter就可以,執行如下命令設置:

MegaCli -PDHSP -Set -PhysDrv[14:1] -a0

局部熱備:(Dedicated HSP)

MegaCli -PDHSP -Set -Dedicated -Array2 -PhysDrv[14:1] -a0

局部熱備裏的Array計算比較麻煩,這裏就要用到上面提到的DG,要按DG的排序累加,一直累加到要添加熱備的VD(要添加熱備的VD也要計算)。
1. 默認設Array爲-1。
2. 如果是RAID0,1,5,6,則Array加1。
3. 如果是RAID10,50,則Array加2。
4. 如果是RAID0,1,5,6,則返回Array最後計算的值。
5. 如果是RAID10,50,則返回Array-1,Array。

[root@kylin ~]# ls -al /dev/disk/by-path/
總用量 0
drwxr-xr-x 2 root root 100 420 18:45 .
drwxr-xr-x 5 root root 100 420 18:41 ..
lrwxrwxrwx 1 root root   9 420 18:41 platform-40000000.pcie-controller-pci-0000:11:00.0-scsi-0:2:0:0 -> ../../sdb
lrwxrwxrwx 1 root root   9 420 18:45 platform-40000000.pcie-controller-pci-0000:11:00.0-scsi-0:2:1:0 -> ../../sdc
lrwxrwxrwx 1 root root   9 420 18:41 platform-40000000.pcie-controller-pci-0000:11:00.0-scsi-0:2:2:0 -> ../../sdd

在系統內查找和VD對應的磁盤

[root@kylin ~]# lspci
00:00.0 PCI bridge: Synopsys, Inc. Device abcd (rev 01)
00:01.0 PCI bridge: Synopsys, Inc. Device abcd (rev 02)
00:02.0 PCI bridge: Synopsys, Inc. Device abcd (rev 01)
00:03.0 PCI bridge: Synopsys, Inc. Device abcd (rev 02)
01:00.0 PCI bridge: PLX Technology, Inc. Device 8725 (rev ca)
01:00.1 System peripheral: PLX Technology, Inc. Device 87d0 (rev ca)
01:00.2 System peripheral: PLX Technology, Inc. Device 87d0 (rev ca)
01:00.3 System peripheral: PLX Technology, Inc. Device 87d0 (rev ca)
01:00.4 System peripheral: PLX Technology, Inc. Device 87d0 (rev ca)
02:01.0 PCI bridge: PLX Technology, Inc. Device 8725 (rev ca)
02:02.0 PCI bridge: PLX Technology, Inc. Device 8725 (rev ca)
02:08.0 PCI bridge: PLX Technology, Inc. Device 8725 (rev ca)
02:09.0 PCI bridge: PLX Technology, Inc. Device 8725 (rev ca)
02:0a.0 PCI bridge: PLX Technology, Inc. Device 8725 (rev ca)
02:0b.0 PCI bridge: PLX Technology, Inc. Device 8725 (rev ca)
02:0c.0 PCI bridge: PLX Technology, Inc. Device 8725 (rev ca)
03:00.0 Fibre Channel: QLogic Corp. ISP2532-based 8Gb Fibre Channel to PCI Express HBA (rev 02)
03:00.1 Fibre Channel: QLogic Corp. ISP2532-based 8Gb Fibre Channel to PCI Express HBA (rev 02)
04:00.0 Ethernet controller: Intel Corporation 82580 Gigabit Network Connection (rev 01)
04:00.1 Ethernet controller: Intel Corporation 82580 Gigabit Network Connection (rev 01)
04:00.2 Ethernet controller: Intel Corporation 82580 Gigabit Network Connection (rev 01)
04:00.3 Ethernet controller: Intel Corporation 82580 Gigabit Network Connection (rev 01)
08:00.0 USB controller: Renesas Technology Corp. uPD720201 USB 3.0 Host Controller (rev 03)
09:00.0 SATA controller: Marvell Technology Group Ltd. Device 9215 (rev 11)
0a:00.0 Serial Attached SCSI controller: LSI Logic / Symbios Logic SAS2008 PCI-Express Fusion-MPT SAS-2 [Falcon] (rev 03)
0c:00.0 PCI bridge: PLX Technology, Inc. Device 8748 (rev ca)
0d:01.0 PCI bridge: PLX Technology, Inc. Device 8748 (rev ca)
0d:08.0 PCI bridge: PLX Technology, Inc. Device 8748 (rev ca)
0d:09.0 PCI bridge: PLX Technology, Inc. Device 8748 (rev ca)
0d:10.0 PCI bridge: PLX Technology, Inc. Device 8748 (rev ca)
0d:11.0 PCI bridge: PLX Technology, Inc. Device 8748 (rev ca)
11:00.0 RAID bus controller: LSI Logic / Symbios Logic MegaRAID SAS 2108 [Liberator] (rev 05)
發表評論