主機型號:ia64 hp superdome server SD32A
存儲型號:XP24000
軟件版本:hpux 11.31 + oracle 11g
LED顯示:attention 紅燈
故障現象:數據庫down,主機down
日誌:
Log Entry 14389: 03/02/2013 12:46:00
Alert level 3: Warning
Keyword: ERM
The Error Response Mode has been determined
Reporting Entity: System Firmware located in cabinet 0, slot 2, cpu 0
Text Message: "CONTINUE"
0x698001ee20e00c18 0x45554e49544e4f43
0x6b0001ee20e00c19 0x010000005131f488
Log Entry 14382: 03/02/2013 12:46:00
Alert level 3: Warning
Keyword: ERM
The Error Response Mode has been determined
Reporting Entity: System Firmware located in cabinet 0, slot 4, cpu 0
Text Message: "CONTINUE"
0x698001ee40e00c0a 0x45554e49544e4f43
0x6b0001ee40e00c0b 0x010000005131f488
處理情況:
1.啓動主機,發現主機籠子不能正常加電
2.登陸主機MP管理系統查看日誌與cell板信息,發現發現 cell 電源 CELL POWER BOARD, SDCPB 存在問題
3.更換主機籠子,更換CPB
4.登陸MP,啓動主機,啓動完畢,重啓操作系統
5.啓動數據庫,查看數據庫狀態。