Dell PowerEdge LCD Status Messages
LCD Status Messages | |||
Source | Error Type | Line 1 Code | Line 2 Message |
BMC | OVERFLOW | E0000 | OVRFLW CHECK LOG |
BIOS | BIOS MULTIBIT ECC | EB10C | ECC Uncorr Err Bank 1 |
BIOS | BIOS MULTIBIT ECC | EB10C | ECC Uncorr Err Bank 2 |
BIOS | BIOS MULTIBIT ECC | EB10C | ECC Uncorr Err Bank 3 |
BIOS | BIOS MULTIBIT ECC | EB10C | ECC Uncorr Err Bank 4 |
BIOS | BIOS MULTIBIT ECC | EB10C | ECC Uncorr Err Bank 5 |
BIOS | BIOS MULTIBIT ECC | EB10C | ECC Uncorr Err Bank 6 |
BIOS | BIOS MULTIBIT ECC | EB10C | ECC Uncorr Err Bank 7 |
BIOS | BIOS MULTIBIT ECC | EB10C | ECC Uncorr Err Bank 8 |
BIOS | BIOS IO CHANNEL CHK | EB113 | I/O Channel Chk |
BIOS | BIOS PCI PARITY | EB113 | PCI Parity Err |
BIOS | BIOS PCI SYSTEM | EB113 | PCI System Err |
BIOS | BIOS SBE LOG DISABLED | IB110 | SBE Log Disabled |
BIOS | BIOS LOGGING DISABLED | IB110 | Logging Disabled |
BIOS | BIOS UNKNOWN | EB112 | Unknown |
BIOS | BIOS CPU PROTOCOL | EB107 | CPU Protocol Err |
BIOS | BIOS CPU BUS | EB107 | CPU Bus PERR |
BIOS | BIOS CPU INIT | EB107 | CPU Init Err |
BIOS | BIOS CPU MACHINE CHK | EB107 | CPU Machine Chk |
BIOS | BIOS MEM SPARED | EB107 | Memory Spared |
BIOS | BIOS MEM MIRRORED | EB107 | Memory Mirrored |
BIOS | BIOS MEM RAID BANK | EB107 | Memory Raid |
BIOS | BIOS MEM HOT ADD | EB107 | Memory Added |
BIOS | BIOS MEM HOT REMOVE | EB107 | Memory Removed |
BIOS | BIOS FATAL PCI EX | EB107 | PCIE Fatal Err |
BIOS | BIOS CHIPSET ERR | EB107 | Chipset Err |
BMC | CPU 1 TEMP | E0119 | Temp PROC 1 |
BMC | CPU 2 TEMP | E0119 | Temp PROC 2 |
BMC | CPU 1 STATUS | E0276 | PROC 1 STATUS |
BMC | CPU 2 STATUS | E0276 | PROC 2 STATUS |
BMC | CPU 1 VCORE | E0276 | PROC 1 VCORE |
BMC | CPU 2 VCORE | E0276 | PROC 2 VCORE |
BMC | SYSBOARD AMB TEMP | E0119 | Temp Ambient |
BMC | BMC TEMP PLANAR | E0119 | Temp BMC |
BMC | RISER TEMP | E0119 | Temp RISER |
BMC | CMOS BATTERY | E0212 | Volt Batt CMOS |
BMC | ROMB PRESENCE | EFFF2 | ROMB PRESENCE |
BMC | ROMB BATTERY | E0212 | Volt Batt ROMB |
BMC | CPU VTT | E0212 | PROC VTT |
BMC | PG 1 5V | E0212 | Volt PG 1 5V |
BMC | PG 1 8V | E0212 | Volt PG 1 8V |
BMC | PG 3 3 V | E0212 | Volt PG 3 3V |
BMC | PG 5 V | E0212 | Volt PG 5 V |
BMC | PG 1 35 V | E0212 | Volt PG 1 35V |
BMC | PG 1 8 VID V | E0212 | Volt PG 1 8V Video |
BMC | PG FIBER CHANNEL | E0212 | Volt PG Fiber Channel |
BMC | RISER 5 V | E0212 | Volt RISER 5V |
BMC | PG RISER | E0212 | Volt RISER |
BMC | FAN 1A RPM | E0412 | RPM Fan 1A |
BMC | FAN 1B RPM | E0412 | RPM Fan 1B |
BMC | FAN 2A RPM | E0412 | RPM Fan 2A |
BMC | FAN 2B RPM | E0412 | RPM Fan 2B |
BMC | FAN 3A RPM | E0412 | RPM Fan 3A |
BMC | FAN 3B RPM | E0412 | RPM Fan 3B |
BMC | FAN 4A RPM | E0412 | RPM Fan 4A |
BMC | FAN 4B RPM | E0412 | RPM Fan 4B |
BMC | FAN 5A RPM | E0412 | RPM Fan 5A |
BMC | FAN 5B RPM | E0412 | RPM Fan 5B |
BMC | FAN 6A RPM | E0412 | RPM Fan 6A |
BMC | FAN 6B RPM | E0412 | RPM Fan 6B |
BMC | FAN 1 RPM | E0412 | RPM Fan 1 |
BMC | FAN 2 RPM | E0412 | RPM Fan 2 |
BMC | FAN 3 RPM | E0412 | RPM Fan 3 |
BMC | FAN 4 RPM | E0412 | RPM Fan 4 |
BMC | FAN 5 RPM | E0412 | RPM Fan 5 |
BMC | FAN 6 RPM | E0412 | RPM Fan 6 |
BMC | FAN 7 RPM | E0412 | RPM Fan 7 |
BMC | FAN 8 RPM | E0412 | RPM Fan 8 |
BMC | FAN 9 RPM | E0412 | RPM Fan 9 |
BMC | FAN 1c RPM | E0412 | RPM Fan 1 |
BMC | FAN 2c RPM | E0412 | RPM Fan 2 |
BMC | FAN 3c RPM | E0412 | RPM Fan 3 |
BMC | FAN 4c RPM | E0412 | RPM Fan 4 |
BMC | FAN 5c RPM | E0412 | RPM Fan 5 |
BMC | FAN 6c RPM | E0412 | RPM Fan 6 |
BMC | FAN 7c RPM | E0412 | RPM Fan 7 |
BMC | FAN 8c RPM | E0412 | RPM Fan 8 |
BMC | FAN 9c RPM | E0412 | RPM Fan 9 |
BMC | FAN REDUNDANCY | E0412 | FAN Redundancy Lost |
BMC | PS1 PRESENCE | E0876 | PS 1 Missing |
BMC | PS1 PRESENCE | E0876 | PS 1 Status |
BMC | PS1 PRESENCE | E0876 | PS 1 Predictive |
BMC | PS1 PRESENCE | E0876 | PS 1 AC LOST |
BMC | PS1 PRESENCE | E0876 | PS 1 AC RANGE |
BMC | PS1 PRESENCE | E0876 | PS 1 AC RANGE |
BMC | PS2 PRESENCE | E0876 | PS 2 Missing |
BMC | PS2 PRESENCE | E0876 | PS 2 Status |
BMC | PS2 PRESENCE | E0876 | PS 2 Predictive |
BMC | PS2 PRESENCE | E0876 | PS 2 AC LOST |
BMC | PS2 PRESENCE | E0876 | PS 2 AC RANGE |
BMC | PS2 PRESENCE | E0876 | PS 2 AC RANGE |
BMC | PS REDUNDANCY | E0880 | PS Redundancy Lost |
BMC | INTRUSION | IS000 | Intrusion |
BMC | OS WATCHDOG | E02F1 | OS Hang |
BMC | CPU1 IERR | E07F0 | PROC 1 IERR |
BMC | CPU1 THERMTRIP | E07FA | PROC 1 Thermtrip |
BMC | CPU1 CONFIG ERROR | E0780 | PROC 1 Config Error |
BMC | CPU 1 PRESENCE | E0780 | PROC 1 Presence |
BMC | CPU1 DISABLED | E0780 | PROC 1 Disabled |
BMC | CPU1 TERM PRESENCE | E0780 | PROC 1 Terminator |
BMC | CPU1 THROTTLED | E07FA | PROC 1 Throttled |
BMC | CPU2 IERR | E07F0 | PROC 2 IERR |
BMC | CPU2 THERMTRIP | E07FA | PROC 2 Thermtrip |
BMC | CPU2 CONFIG ERROR | E0780 | PROC 2 Config Error |
BMC | CPU 2 PRESENCE | E0780 | PROC 2 Presence |
BMC | CPU2 DISABLED | E0780 | PROC 2 Disabled |
BMC | CPU2 TERM PRESENCE | E0780 | PROC 2 Terminator |
BMC | CPU2 THROTTLED | E07FA | PROC 2 Throttled |
BMC | CPU3 IERR | E07F0 | PROC 3 IERR |
BMC | CPU3 THERMTRIP | E07FA | PROC 3 Thermtrip |
BMC | CPU3 CONFIG ERROR | E0780 | PROC 3 Config Error |
BMC | CPU3 PRESENCE | E0780 | PROC 3 Presence |
BMC | CPU3 DISABLED | E0780 | PROC 3 Disabled |
BMC | CPU3 TERM PRESENCE | E0780 | PROC 3 Terminator |
BMC | CPU3 THROTTLED | E07FA | PROC 3 Throttled |
BMC | CPU4 IERR | E07F0 | PROC 4 IERR |
BMC | CPU4 THERMTRIP | E07FA | PROC 4 Thermtrip |
BMC | CPU4 CONFIG ERROR | E0780 | PROC 4 Config Error |
BMC | CPU4 PRESENCE | E0780 | PROC 4 Presence |
BMC | CPU4 DISABLED | E0780 | PROC 4 Disabled |
BMC | CPU4 TERM PRESENCE | E0780 | PROC 4 Terminator |
BMC | CPU4 THROTTLED | E07FA | PROC 4 Throttled |
BMC | VRM 1 PG | E0276 | VRM 1 PG |
BMC | VRM 2 PG | E0276 | VRM 2 PG |
BMC | VRM 3 PG | E0276 | VRM 3 PG |
BMC | VRM 4 PG | E0276 | VRM 4 PG |
BMC | VCACHE 1 PG | E0276 | VCACHE 1 PG |
BMC | VCACHE 2 PG | E0276 | VCACHE 2 PG |
BP | SCSI DRIVE | E0D76 | BP Drive 0 |
BP | SCSI DRIVE | E0D76 | BP Drive 1 |
BP | SCSI DRIVE | E0D76 | BP Drive 2 |
BP | SCSI DRIVE | E0D76 | BP Drive 3 |
BP | SCSI DRIVE | E0D76 | BP Drive 4 |
BP | SCSI DRIVE | E0D76 | BP Drive 5 |
BP | SCSI DRIVE | E0D76 | BP Drive 6 |
BP | SCSI DRIVE | E0D76 | BP Drive 7 |
BP | SCSI DRIVE | E0D76 | BP Drive 8 |
BP | SCSI DRIVE | E0D76 | BP Drive 9 |
BP | SCSI DRIVE | E0D76 | BP Drive 10 |
BP | SCSI DRIVE | E0D76 | BP Drive 11 |
BP | SCSI DRIVE | E0D76 | BP Drive 0 |
BP | SCSI DRIVE | E0D76 | BP Drive 1 |
BP | SCSI DRIVE | E0D76 | BP Drive 2 |
BP | SCSI DRIVE | E0D76 | BP Drive 3 |
BP | SCSI DRIVE | E0D76 | BP Drive 4 |
BP | SCSI DRIVE | E0D76 | BP Drive 6 |
BP | SCSI DRIVE | E0D76 | BP Drive 7 |
BP | SCSI DRIVE | E0D76 | BP Drive 8 |
BP | SCSI DRIVE | E0D76 | BP Drive 9 |
BP | SCSI DRIVE | E0D76 | BP Drive 10 |
BP | SCSI DRIVE | E0D76 | BP Drive 11 |
BP | SCSI DRIVE | E0D76 | 1×2 Drive 0 |
BP | SCSI DRIVE | E0D76 | 1×2 Drive 1 |
BP | SCSI CONNECTOR | E0D76 | SCSI Connector |
PBP | DISK DRIVE BAY SECONDARY PRESENCE | E0D76 | DISK DRIVE BAY SECOND |