There is a configuration file LINSlaveConformanceTest.cfg for LIN slave conformance test at C:\Users\Public\Documents\Vector\CANoe\Sample Configurations 11.0.55\LIN\LINSlaveConformanceTest\.
Make sure the CANoe has LIN option and has LINpiggy inside the HW. Connect the slave device with CANoe.
Base on this, we can do some modifications to perform the real LIN slave conformance test as below.
1. Modified the simulation setup, load the real LDF file for your product instead of using the dfault one. Set CANoe LIN channel and add nodes to the network.
2. Right click on the "LIN slave conformance tester 1" as below
to config the settings for the tests. Select your slave node and click "generate XML".
3. Then the test cases window will be poped up as below.
4. Select the cases you want to perform and click the start icon at lower right corner to start the testing, you can get the test report by clicking the lower left solid triangle icon of above picture. The test report is like: