Show Controllers E1 命令的講解

       純搬運工,從Cisco官網轉載,因爲很多專業術語不知如何翻譯,自己也不是很理解,希望以後能補充完整。Cisco官網文檔 Understanding the show controllers e1 command 編號:9160

______________________________________________________________________________________________-----

Show Controllers E1 命令用於顯示E1控制器的硬件狀態。

Show Controllers E1 輸出舉例

Bru#show controllers e1  
E1 0 is up.    
    Applique type is Channelized E1 ? balanced    
    No alarms detected.    
    Version info of Slot 0: HW: 2, Firmware: 4, PLD Rev: 2    
Manufacture Cookie is not programmed. 
Framing is CRC4, Line Code is HDB3, Clock Source is Line Primary. 
   Data in current interval (251 seconds elapsed):    
     0 Line Code Violations, 0 Path Code Violations    
     0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins    
     0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 0 Unavail Secs    
Total Data (last 24 hours)    
    0 Line Code Violations, 0 Path Code Violations,    
    0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins,    
    0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 0 Unavail Secs


E1 1 is down.    
    Applique type is Channelized E1 ? balanced    
    Transmitter is sending remote alarm.    
    Receiver has loss of signal.    
    Version info of Slot 0: HW: 2, Firmware: 4, PLD Rev: 2    
Manufacture Cookie is not programmed.    
Framing is CRC4, Line Code is HDB3, Clock Source is Line Secondary.    
  Data in current interval (200 seconds elapsed):    
       0 Line Code Violations, 0 Path Code Violations    
       0 Slip Secs, 200 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins    
       0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 200 Unavail Secs    
Total Data (last 24 hours)    
       0 Line Code Violations, 0 Path Code Violations,    
       0 Slip Secs, 86400 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins,    
       0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 86400 Unavail Secs


E1 2 is administratively down.    
    Applique type is Channelized E1 ? balanced    
    Transmitter is sending remote alarm.    
    Receiver has loss of signal.    
    Version info of Slot 0: HW: 2, Firmware: 4, PLD Rev: 2    
Manufacture Cookie is not programmed.    
Framing is CRC4, Line Code is HDB3, Clock Source is Internal.    
   Data in current interval (249 seconds elapsed):    
       0 Line Code Violations, 0 Path Code Violations    
       0 Slip Secs, 249 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins    
       0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 249 Unavail Secs    
  Total Data (last 24 hours)    
      0 Line Code Violations, 0 Path Code Violations,    
      0 Slip Secs, 86400 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins,    
      0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 86400 Unavail Secs

字段說明

E1 0 is up顯示E1控制器的的狀態。 這個狀態可以是UP,Down 或 Administratively Down。打環時會顯示Locally looped 或remotely looped。
Applique Type控制器的Applique Type 和 indicate 可以是Blanced 或 Unbalanced
Framing默認是有CRC4校驗的
Line Code默認E1線路的line code是HDB3
No Alarms detected

如監測到任何報警信息,會顯示在當前位置。可能會出現的報警信息有:

  • Transmitter is sending remote alarm.

  • Transmitter is sending alarm indication            
    signal (AIS)。

  • Receiver has loss of signal.

  • Receiver is getting AIS.

  • Receiver has loss of frame. 

  • Receiver has remote alarm. 
    Receiver has no alarms. 


Data in current interval(251 seconds elapsed)

Shows the current accumulation period, which          
rolls into a 24 hour accumulation every 15            
minutes. The accumulation period is from one            
to 900 seconds. The oldest 15?minute period            
falls off the back of the 24?hour accumulation            
buffer.

Line Code Violations

Indicates the occurrence of either a Bipolar          
Violation (BPV) or Excessive Zeros (EXZ)            
error event.

Path Code Violations

Indicates a frame synchronization bit error in          
the D4 and E1?no CRC formats, or a CRC            
error in the Extended Superframe (ESF) and            
E1?CRC formats.

Slip Secs

Indicates the replication or deletion of the          
payload bits of a domestic trunk interface            
(DS1) frame. A slip might happen when there            
is a difference between the timing of a            
synchronous receiving terminal and the            
received signal.

Fr Loss Secs

Indicates the number of seconds an Out of          
Frame (OOF) error is detected.

Line Err secs

Line Errored Seconds (LES) is a second in          
which one or more Line Code Violation errors            
are detected.

Degraded Mins

A degraded minute is one in which the          
estimated error rate exceeds 1E?6 but does not            
exceed 1E?3.

Errored secs

     In ESF and E1 CRC links, an errored second is          
a second in which one of the following defects            
is detected:

  • One or more Path Code Violations.

  • One or more Controlled Slip events. 

For SF and E1 no?CRC links, the presence of          
Bipolar Violations also triggers an errored            
second.

Bursty Err secs

A second with more than one but fewer than          
320 Path Coding Violation errors, no Severely            
Errored Frame defects and no detected            
incoming AIS defects. Controlled slips are not            
included in this parameter.

Severly Err Secs

     For ESF signals, this is a second in which one          
of the following defects is detected:

  • 320 or more Path Code Violation            
    errors.

  • One or more Out of Frame defects.

  • An AIS defect.

For E1?CRC signals, a second with one of the          
following errors:

  • 832 or more Path Code Violation            
    errors.

  • One or more Out of Frame defects

     For E1?nonCRC signals, this is a second with          
2048 Line Code Violations or more. For D4            
signals, this means a count of 1?second            
intervals with Framing Errors, or an Out of            
Frame defect, or 1544 Line Code Violations

Unavail Secs

     For E1?nonCRC signals, this is a second with          
2048 Line Code Violations or more. For D4            
signals, this means a count of 1?second            
intervals with Framing Errors, or an Out of            
Frame defect, or 1544 Line Code Violations

  

發表評論