升級M1000E交換機FW

1. 用USB serial cable/null modem 一端連接電腦串口,一端連接交換機usb口

usb null modem cable

使用終端仿真程序secureCRT/HyperTerminal連接到交換機
參數:
        9600波特率
         8個數據位
         無奇偶校驗
         1個停止位
         無流控制
按<enter>2次或3次開始連接
通過CMC連接:
1 連接到cmc後, 鍵入"connect switch-[n]"連接到指定槽位中的交換機(n代表1,2,3)
cmc-rack1 login: root
Password:

 
Welcome to the CMC - firmware version X08.1.0.200710311456 

 
connect switch-1 

 
Connected to remote port. 

 
Escape character is '^\'. 

 
 console>

 
2 進入CMC命令行模式: 鍵入"<ctrl> \" 按<enter>2次或3次

 
cmc-rack1 login: root 
Password: 

 
Welcome to the CMC - firmware version X08.1.0.200710311456 

 
 $ connect switch-1 

 
Connected to remote port. 
Escape character is '^\'. 

 
 console>  
Type Ctrl-\ here. 

 

 
2 初始化:
console>en          進入特權模式
console#
console#config    進入配置管理
console(config)# ip address 192.168.0.1  255.255.255.0   配置ip及子網掩碼
console(config)# username xxx password passw0rdlevel15 用戶名及密碼
console(config)# end  退出config
console# copy running-config  startup-config  保存配置

 
3查看交換機當前FW版本:
console# show version (顯示如下內容)
Unit    p_w_picpath1    p_w_picpath2    current-active   next-active
1       1.0.0.1       1.0.0.1          p_w_picpath1            p_w_picpath1

 
4  通過TFTPserver將FW最新版本的基礎版本A.1.1.9傳輸到交換機
     console# copy tftp://192.168.0.2/PCM6220vA.1.1.9.stk p_w_picpath
     Management access will be blocked for the duration of the  transfer
     Are you sure you want to start?(y/n) y
     console# show version 顯示如下
      Unit    p_w_picpath1    p_w_picpath2    current-active   next-active
        1       1.0.0.1     A.1.1.9         p_w_picpath1              p_w_picpath1
5 激活A.1.1.9並替換當前版本
console# boot system p_w_picpath2
6升級引導代碼並重啓交換機
console# update bootcode
Update bootcode and reset (Y/N)?y
Management switch has unsaved changes
Are you sure you want to continue?(Y/N)y
7重複上述步驟將FW更新到4.2.1.3:
console#copy tftp://192.168.0.1/PCM6220v4.2.1.3.stk p_w_picpath
Management access will be blocked for the duration of the transfer
Are you sure you want to start?(y/n) y
console# show version
Unit    p_w_picpath1    p_w_picpath2    current-active   next-active
1       4.2.1.3       A.1.1.9              p_w_picpath2p_w_picpath2
console# boot system p_w_picpath1
console#update bootcode
Update bootcode and reset (Y/N)?y
 
Management switch has unsaved changes
Are you sure you want to continue?(Y/N)y
 
升級FW三步驟: 1. copy 2. boot system p_w_picpathx 3. update bootcode