【OK6410裸機程序】時鐘初始化

#define APLL_LOCK (*((volatile unsigned long *)0x7E00F000))
#define MPLL_LOCK (*((volatile unsigned long *)0x7E00F004))
#define EPLL_LOCK (*((volatile unsigned long *)0x7E00F008))

#define OTHERS    (*((volatile unsigned long *)0x7e00f900))

#define CLK_DIV0  (*((volatile unsigned long *)0x7E00F020))

#define ARM_RATIO    0   /* ARMCLK = DOUTAPLL / (ARM_RATIO + 1)    */
#define HCLKX2_RATIO 4   /* HCLKX2 = HCLKX2IN / (HCLKX2_RATIO + 1) = 100MHz */
#define HCLK_RATIO   0   /* HCLK = HCLKX2 / (HCLK_RATIO + 1)   = 100MHz       */
#define PCLK_RATIO   1   /* PCLK   = HCLKX2 / (PCLK_RATIO + 1) = 50MHz    */
#define MPLL_RATIO   0   /* DOUTMPLL = MOUTMPLL / (MPLL_RATIO + 1)     */


#define APLL_CON  (*((volatile unsigned long *)0x7E00F00C))
#define APLL_CON_VAL  ((1<<31) | (250 << 16) | (3 << 8) | (1))  /* FOUT_APLL=500MHz*/

#define MPLL_CON  (*((volatile unsigned long *)0x7E00F010))
#define MPLL_CON_VAL  ((1<<31) | (250 << 16) | (3 << 8) | (1)) /* FOUT_MPLL=500MHz*/

#define CLK_SRC  (*((volatile unsigned long *)0x7E00F01C))

void clock_init(void)
{
	APLL_LOCK = 0xffff;
	MPLL_LOCK = 0xffff;
	EPLL_LOCK = 0xffff;

	/* set async mode 當CPU時鐘 != HCLK時,要設爲異步模式 */
	OTHERS &= ~0xc0;
	while ((OTHERS & 0xf00) != 0);

	CLK_DIV0 = (ARM_RATIO) | (MPLL_RATIO << 4) | (HCLK_RATIO << 8) | (HCLKX2_RATIO << 9) | (PCLK_RATIO << 12);
	
	APLL_CON = APLL_CON_VAL;  /* 500MHz */
	MPLL_CON = MPLL_CON_VAL;  /* 500MHz */

	CLK_SRC = 0x03;
}

配置過程參考下圖,從右向左配置。

1. 配置同步模式,異步模式主要用於ARMCLK=667MHz時的配置。

當APLL_OUT=667MHZ時 ARMCLK:HCLKx2:HCLK=1:2.5:5

當APLL_OUT爲533MHZ或以下時,只需保證ARMCLK=n*HCLK即可。

The clock ratio between ARMCLK and HCLK must be integer to use synchronous interface between ARM core
and AXI bus interface. S3C6410X does not have any limitation up to 533MHz synchronous interface, i.e.,
ARMCLK = 533MHz, HCLKX2= 266MHz, HCLK = 133MHz. However, there is some constraints over 533MHz,
typically 667MHz interface. The supported clock ratio is only 1:2.5:5 (ARMCLK = 667MHz, HCLKX2=266MHz,
HCLK = 133MHz).
 

配置同步模式:MISC_CON[SYNC667]=1;OTHERS[SYNCMODE]=1;OTHERS[SYNCMUXSEL]=1

2.配置CLK_DIV0寄存中的各種分頻係數,注意HCLK與PCLK的頻率必須是偶數分頻。

3.配置APLL_CON&MPLL_CON,使能PLL並設置分頻係數。

4. 配置CLK_SRC,選擇PLL輸出頻率作爲後續分頻的輸入。


關於OK6410的一些頻率參數:

ARMCLK最大667MHz

HCLKx2最大266MHz,爲DDR0&DDR1提供時鐘

HCLK最大133MHz

PCLK最大66MHz


4.關於Lock time的說明

PLL輸入時鐘變化或者分頻係數變化後,需要一段時間鎖定頻率,這段時間內,輸出一直是0.鎖定時間單位是輸入時鐘週期。

A PLL requires locking period when input frequency is changed or frequency division (multiplication) values are
changed. PLL_LOCK register specifies this locking period, which is based on PLL’s source clock. During this
period, output will be masked ‘0’
 。